Roof & Septic

Septic tank size calculator

A tank size to plan for, by bedrooms, and what 15 US states ask for in their own rules.

Plan for a 1,000 gallon tank.

The rule used. A planning figure: 1,000 gallons for up to 3 bedrooms, then 250 more for each bedroom after that.

Your county decides. Massachusetts and Ohio ask for more than this for 3 bedrooms. Pick your state for its own number.

Show the working
  1. Bedrooms: 3 bedrooms.
  2. Starting size: the planning figure is 1,000 gal for 1 to 3 bedrooms.
  3. Extra bedrooms: 0 bedrooms above 3 × 250 gal = 0 gal.
  4. Total: 1,000 + 0 = 1,000 gal.

This is a planning figure, not your state's or your county's rule. How we calculate

Your numbers

How many bedrooms does the house have, or will it have?

Bedrooms, not people: codes size the tank by bedrooms, because the next owners may be a bigger family.

You can skip this. We have read the rules of 15 states so far; for any other state, leave it as it is.

For homes in the United States. This page uses US state rules and US gallons. Its answers do not apply in Canada, the UK, Australia or anywhere else.

Tank size by bedrooms

The calculator uses a planning figure: 1,000 gallons for up to 3 bedrooms, then 250 more for each bedroom after that. It is not any one state's rule, though New York's table matches it. Most of the states we checked ask for the same or a little less, and Massachusetts and Ohio ask for more.

Pick your state under the bedrooms and the answer changes to that state's own minimum, read from its rule.

BedroomsPlanning figure
1 to 31,000 gal
41,250 gal
51,500 gal
61,750 gal

What 15 states ask for

These are the smallest tanks each state's own rule allows for a house, in gallons. Your county or town can ask for more, so check with the health department before you buy a tank or draw a plan.

Read in each state's own rule and checked on 18 November 2026. Counties and towns can be stricter. * Worked out from the state's formula or flow table.
State1 or 2 bedrooms345More bedroomsThe rule
Alabama1,0001,0001,0001,500250 more for each bedroom over 5Ala. Admin. Code ch. 420-3-1
California7501,0001,2001,5001,500 covers 5 or 6 bedrooms. Extra bedrooms add 150 eachState Water Board OWTS Policy, with the California Plumbing Code, Appendix H
Florida *9009001,0501,200Set by daily flow. Each extra bedroom adds 60 gallons a day, which gives 1,350 for 6 or 7 bedroomsFla. Admin. Code ch. 62-6
Georgia1,0001,0001,0001,250250 more for each bedroom over 4Ga. Comp. R. & Regs. ch. 511-3-1
Indiana7501,0001,2501,500300 more for each bedroom over 5410 IAC 6-8.3
Massachusetts *1,5001,5001,5001,500Twice the daily flow and never under 1,500, which is passed at 7 bedrooms (1,540), then 220 more for each310 CMR 15.000 (Title 5)
MichiganSet by the local health departmentState septic program
New York1,0001,0001,2501,5001,750 for 6 bedrooms, then 250 more for each10 NYCRR Appendix 75-A
North Carolina1,0001,0001,0001,250By formula over 5 bedrooms: about 1,342 for 6, then about 140 more for each15A NCAC 18E
Ohio1,0001,5002,0002,0002,500 or more for 6 bedrooms and up. The rule adds 250 a bedroom, and its wording leaves the count unclearOhio Admin. Code ch. 3701-29
Pennsylvania *9009001,2501,400150 more for each bedroom over 525 Pa. Code chs. 72 and 73
Tennessee7509001,0001,250250 more for each extra bedroomTenn. Comp. R. & Regs. 0400-48-01
Texas *7501,0001,2501,250Set by daily flow: about 1,313 for 6 bedrooms30 Tex. Admin. Code ch. 285
Virginia7509001,2001,500The table stops at 5 bedrooms12VAC5-610
Washington1,0001,0001,0001,250250 more for each bedroom over 4WAC 246-272A

The two national model codes that many local codes are built on start lower. Both list 750 gallons for 1 or 2 bedrooms, 1,000 for 3 and 1,200 for 4. The EPA's design manual, which prints one of those tables, adds that many states have raised the minimum to 1,000 gallons or more.

What can change the size where you live

The county or state health department sets the real minimum, and it can differ from the planning figure. The rules often change with the number of bedrooms, with extras such as a garbage disposal or a large tub, and with the kind of system.

How a state counts bedrooms matters as much as its table. Indiana counts any room of 70 square feet or more that has a window or door to escape by and could be slept in. Massachusetts presumes every house has at least 3 bedrooms, and counts a house with more than 8 rooms at half its rooms. In New York an attic that could be finished later counts as a bedroom.

Ask the health department for the written rule that applies to your lot before you buy a tank or draw a plan.

Already have a tank? How to find its size

  1. Ask the county health department for the septic permit or the as-built record for your address. It usually lists the tank size.
  2. Look at the receipt from the last pumping. Many list the gallons pumped or the tank size.
  3. Have it measured at the next pumping. The pumper can measure the tank while it is open and tell you its size: length × width × liquid depth in feet × 7.48 gives gallons.

Don't open a tank or lean into one yourself: the gases inside are dangerous. If the numbers disagree, trust the permit record and ask a septic pro to confirm.

Common questions

Is a bigger tank better?

Not by itself. A larger tank gives solids more time to settle, but the drain field still has to take the water that leaves it. The size your county requires is the one to plan for.

Do I count a room that could be a bedroom?

Often yes. Many places count any room that could be used as a bedroom, such as a den with a closet. Ask the health department how it counts rooms.

Does a garbage disposal change the size?

It depends on the state. Georgia asks for a tank 50% bigger. New York adds 250 gallons and asks for a two-compartment tank or two tanks in a row. Massachusetts asks for the two compartments but keeps the size. California, Ohio and Pennsylvania make no change. Your county decides.

Where this comes from

Sources last checked 18 November 2026.

Related

Last reviewed 18 November 2026 · How we calculate · Report a wrong answer