Septic tank size calculator
A tank size to plan for, by bedrooms, and what 15 US states ask for in their own rules.
Plan for a 1,000 gallon tank.
The rule used. A planning figure: 1,000 gallons for up to 3 bedrooms, then 250 more for each bedroom after that.
Your county decides. Massachusetts and Ohio ask for more than this for 3 bedrooms. Pick your state for its own number.
Show the working
- Bedrooms: 3 bedrooms.
- Starting size: the planning figure is 1,000 gal for 1 to 3 bedrooms.
- Extra bedrooms: 0 bedrooms above 3 × 250 gal = 0 gal.
- Total: 1,000 + 0 = 1,000 gal.
This is a planning figure, not your state's or your county's rule. How we calculate
For homes in the United States. This page uses US state rules and US gallons. Its answers do not apply in Canada, the UK, Australia or anywhere else.
Tank size by bedrooms
The calculator uses a planning figure: 1,000 gallons for up to 3 bedrooms, then 250 more for each bedroom after that. It is not any one state's rule, though New York's table matches it. Most of the states we checked ask for the same or a little less, and Massachusetts and Ohio ask for more.
Pick your state under the bedrooms and the answer changes to that state's own minimum, read from its rule.
| Bedrooms | Planning figure |
|---|---|
| 1 to 3 | 1,000 gal |
| 4 | 1,250 gal |
| 5 | 1,500 gal |
| 6 | 1,750 gal |
What 15 states ask for
These are the smallest tanks each state's own rule allows for a house, in gallons. Your county or town can ask for more, so check with the health department before you buy a tank or draw a plan.
| State | 1 or 2 bedrooms | 3 | 4 | 5 | More bedrooms | The rule |
|---|---|---|---|---|---|---|
| Alabama | 1,000 | 1,000 | 1,000 | 1,500 | 250 more for each bedroom over 5 | Ala. Admin. Code ch. 420-3-1 |
| California | 750 | 1,000 | 1,200 | 1,500 | 1,500 covers 5 or 6 bedrooms. Extra bedrooms add 150 each | State Water Board OWTS Policy, with the California Plumbing Code, Appendix H |
| Florida * | 900 | 900 | 1,050 | 1,200 | Set by daily flow. Each extra bedroom adds 60 gallons a day, which gives 1,350 for 6 or 7 bedrooms | Fla. Admin. Code ch. 62-6 |
| Georgia | 1,000 | 1,000 | 1,000 | 1,250 | 250 more for each bedroom over 4 | Ga. Comp. R. & Regs. ch. 511-3-1 |
| Indiana | 750 | 1,000 | 1,250 | 1,500 | 300 more for each bedroom over 5 | 410 IAC 6-8.3 |
| Massachusetts * | 1,500 | 1,500 | 1,500 | 1,500 | Twice the daily flow and never under 1,500, which is passed at 7 bedrooms (1,540), then 220 more for each | 310 CMR 15.000 (Title 5) |
| Michigan | Set by the local health department | State septic program | ||||
| New York | 1,000 | 1,000 | 1,250 | 1,500 | 1,750 for 6 bedrooms, then 250 more for each | 10 NYCRR Appendix 75-A |
| North Carolina | 1,000 | 1,000 | 1,000 | 1,250 | By formula over 5 bedrooms: about 1,342 for 6, then about 140 more for each | 15A NCAC 18E |
| Ohio | 1,000 | 1,500 | 2,000 | 2,000 | 2,500 or more for 6 bedrooms and up. The rule adds 250 a bedroom, and its wording leaves the count unclear | Ohio Admin. Code ch. 3701-29 |
| Pennsylvania * | 900 | 900 | 1,250 | 1,400 | 150 more for each bedroom over 5 | 25 Pa. Code chs. 72 and 73 |
| Tennessee | 750 | 900 | 1,000 | 1,250 | 250 more for each extra bedroom | Tenn. Comp. R. & Regs. 0400-48-01 |
| Texas * | 750 | 1,000 | 1,250 | 1,250 | Set by daily flow: about 1,313 for 6 bedrooms | 30 Tex. Admin. Code ch. 285 |
| Virginia | 750 | 900 | 1,200 | 1,500 | The table stops at 5 bedrooms | 12VAC5-610 |
| Washington | 1,000 | 1,000 | 1,000 | 1,250 | 250 more for each bedroom over 4 | WAC 246-272A |
- California. From the state plumbing code. A county can amend it. California has no single statewide design code. The state policy's default applies only where a county has no approved program of its own, and most counties have one.
- Florida. The rule sizes by the larger of the bedroom count and the floor area, so a big house can need the next size up.
- Indiana. Indiana adopted amendments on 21 October 2026 that were not yet in force when we checked. They keep the same tank sizes, daily flow and trench widths.
- Michigan. Michigan leaves one- and two-family homes to each local health department. Ask yours for its sanitary code.
- New York. In New York, counties and watershed agencies can be stricter than the state.
- Ohio. Ohio's figures are total capacity. From 3 bedrooms up it is split between two tanks or two compartments.
- Texas. For a house without water-saving fixtures. The rule also sizes by floor area, so a large house can need the next size up.
The two national model codes that many local codes are built on start lower. Both list 750 gallons for 1 or 2 bedrooms, 1,000 for 3 and 1,200 for 4. The EPA's design manual, which prints one of those tables, adds that many states have raised the minimum to 1,000 gallons or more.
What can change the size where you live
The county or state health department sets the real minimum, and it can differ from the planning figure. The rules often change with the number of bedrooms, with extras such as a garbage disposal or a large tub, and with the kind of system.
How a state counts bedrooms matters as much as its table. Indiana counts any room of 70 square feet or more that has a window or door to escape by and could be slept in. Massachusetts presumes every house has at least 3 bedrooms, and counts a house with more than 8 rooms at half its rooms. In New York an attic that could be finished later counts as a bedroom.
Ask the health department for the written rule that applies to your lot before you buy a tank or draw a plan.
Already have a tank? How to find its size
- Ask the county health department for the septic permit or the as-built record for your address. It usually lists the tank size.
- Look at the receipt from the last pumping. Many list the gallons pumped or the tank size.
- Have it measured at the next pumping. The pumper can measure the tank while it is open and tell you its size: length × width × liquid depth in feet × 7.48 gives gallons.
Don't open a tank or lean into one yourself: the gases inside are dangerous. If the numbers disagree, trust the permit record and ask a septic pro to confirm.
Common questions
Is a bigger tank better?
Not by itself. A larger tank gives solids more time to settle, but the drain field still has to take the water that leaves it. The size your county requires is the one to plan for.
Do I count a room that could be a bedroom?
Often yes. Many places count any room that could be used as a bedroom, such as a den with a closet. Ask the health department how it counts rooms.
Does a garbage disposal change the size?
It depends on the state. Georgia asks for a tank 50% bigger. New York adds 250 gallons and asks for a two-compartment tank or two tanks in a row. Massachusetts asks for the two compartments but keeps the size. California, Ohio and Pennsylvania make no change. Your county decides.
- The state rules linked in the table above: each state's minimum tank sizes, its bedroom count and its garbage disposal rule
- U.S. EPA, Onsite Wastewater Treatment Systems Manual (2002), Table 4-13: the International Private Sewage Disposal Code's tank table, and the note that many states start at 1,000 gallons or more
- California Plumbing Code (2025), Appendix H, Table H 201.1(1): the Uniform Plumbing Code's tank table, which California uses
Sources last checked 18 November 2026.
Related